July 2019
Volume 60, Issue 9
Open Access
ARVO Annual Meeting Abstract  |   July 2019
Vitreous body imaging with long-range swept-source optical coherence tomography for detection of opacities
Author Affiliations & Notes
  • Ireneusz Grulkowski
    Institute of Physics, Nicolaus Copernicus University, Torun, Poland
  • Ana Rodriguez-Aramendia
    Instituto de Microcirugía Ocular, Barcelona, Spain
    Center for Sensors, Instruments and Systems Development (CD6), Universidad Politécnica de Cataluña, Barcelona, Spain
  • Daniel Ruminski
    Institute of Physics, Nicolaus Copernicus University, Torun, Poland
  • Silvestre Manzanera
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain
  • Yiwei Chen
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain
  • Juan Mompeán
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain
  • Fernando Diaz Douton
    Center for Sensors, Instruments and Systems Development (CD6), Universidad Politécnica de Cataluña, Barcelona, Spain
  • Jaume Pujol
    Center for Sensors, Instruments and Systems Development (CD6), Universidad Politécnica de Cataluña, Barcelona, Spain
  • J Sebag
    VMR Institute for Vitreous Macula Retina, Huntington Beach, California, United States
  • Pablo Artal
    Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain
  • Footnotes
    Commercial Relationships   Ireneusz Grulkowski, None; Ana Rodriguez-Aramendia, None; Daniel Ruminski, None; Silvestre Manzanera, None; Yiwei Chen, None; Juan Mompeán, None; Fernando Diaz Douton, None; Jaume Pujol, None; J Sebag, None; Pablo Artal, None
  • Footnotes
    Support  European Fund for Regional Development within the Smart Growth Operational Programme 2014–2020 (TEAM Programme, POIR.04.04.00-00-5C9B/17-00), by the European Research Council SEECAT grant (#ERC-2013-AdG-339228), by the Secretaría de Estado de Investigación, Desarrollo e Innovación (SEIDI; #FIS2016-76163-R), by the Fundación Séneca-Agencia de Ciencia y Tecnología de la Región de Murcia (#19897/GERM/15), and by the European Regional Development Fund (#EU-FEDER), European Union’s Horizon 2020 (BE-OPTICAL 675512); VMR Research Foundation.
Investigative Ophthalmology & Visual Science July 2019, Vol.60, 1291. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Ireneusz Grulkowski, Ana Rodriguez-Aramendia, Daniel Ruminski, Silvestre Manzanera, Yiwei Chen, Juan Mompeán, Fernando Diaz Douton, Jaume Pujol, J Sebag, Pablo Artal; Vitreous body imaging with long-range swept-source optical coherence tomography for detection of opacities. Invest. Ophthalmol. Vis. Sci. 2019;60(9):1291.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To perform enhanced visualization of vitreous opacities in vivo using an optimized SS-OCT instrument with tunable optics and demonstrate characteristic features of vitreous opacities by OCT imaging.

Methods : Long-range SS-OCT instrumentation was operated at the central wavelength of 1 μm and a speed of 30,000 A-scans per second. The axial range of the system enabled in vivo imaging through the entire length of the eye. OCT volumetric data sets consisting of 300x300 A-scans were acquired. Additionally, during scanning, the electrically tunable lens (ETL) changed its focal distance enabling signal enhancement at different depths of the vitreous body. A composite vitreous image was obtained as a sum of the images obtained at different focusing states, with enhanced signals from the vitreous opacities. The optical design of the interface (sample arm) was optimized to maximize the portion of the imaged vitreous. A group of healthy volunteers and patients with vitreous opacities were imaged with ultrasound and SS-OCT to visualize the vitreous body. Different contrast enhancing approaches were implemented to effectively map vitreous opacities.

Results : The performance of the prototype SS-OCT system was optimized to minimize signal drop with depth, to achieve high signal sensitivity, and to confirm scanned area. We obtained OCT tomograms spanning the depth of the entire vitreous for visualization of its scattering properties. The opacities are characterized by increased light scattering, and manifest as a hyper-intense signal behind the posterior surface of the crystalline lens or in front of the retina, or as scattering particles (‘floaters’) inside the vitreous body. A correspondence of OCT images ultrasound images was observed.

Conclusions : Implementation of focus tunable optics into SS-OCT enabled visualization of microstructural changes in vitreous in vivo, primarily as related to opacifications. OCT allowed for characterization of vitreous opacities and comparison of the images with ultrasound. SS-OCT can be a useful diagnostic tool in the high-resolution optical evaluation and management of vitreous opacities.

This abstract was presented at the 2019 ARVO Annual Meeting, held in Vancouver, Canada, April 28 - May 2, 2019.

 

<p style="margin: 0px;"><span style="margin:0px"><font color="#000000" face="Times New Roman" size="3">Figure 1. OCT imaging of vitreous anterior (a) and posterior (b) interfaces.</font></span></p>

<p style="margin: 0px;"><span style="margin:0px"><font color="#000000" face="Times New Roman" size="3">Figure 1. OCT imaging of vitreous anterior (a) and posterior (b) interfaces.</font></span></p>

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×