Investigative Ophthalmology & Visual Science Cover Image for Volume 61, Issue 7
June 2020
Volume 61, Issue 7
Free
ARVO Annual Meeting Abstract  |   June 2020
Effect of temporary full-field defocus on ocular biometric components and their subsequent normalization: a pilot study
Author Affiliations & Notes
  • Ryo Kubota
    Kubota Pharmaceutical Holdings Co., Ltd., Seattle, Washington, United States
  • Nabin R Joshi
    Institute for vision research, New york, New York, United States
  • arkady selenow
    Institute for vision research, New york, New York, United States
  • amitava gupta
    Kubota Pharmaceutical Holdings Co., Ltd., Seattle, Washington, United States
  • steven ali
    Institute for vision research, New york, New York, United States
  • inna samandarova
    Institute for vision research, New york, New York, United States
  • maksud oliva
    Institute for vision research, New york, New York, United States
  • Kenneth J Ciuffreda
    SUNY College of Optometry, New York, United States
  • Footnotes
    Commercial Relationships   Ryo Kubota, Acucela Inc (S); Nabin Joshi, None; arkady selenow, Acucela Inc (C); amitava gupta, Acucela Inc (E); steven ali, None; inna samandarova, None; maksud oliva, None; Kenneth Ciuffreda, None
  • Footnotes
    Support  ACUCELA INC.
Investigative Ophthalmology & Visual Science June 2020, Vol.61, 2700. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Ryo Kubota, Nabin R Joshi, arkady selenow, amitava gupta, steven ali, inna samandarova, maksud oliva, Kenneth J Ciuffreda; Effect of temporary full-field defocus on ocular biometric components and their subsequent normalization: a pilot study. Invest. Ophthalmol. Vis. Sci. 2020;61(7):2700.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : In this pilot study, we observed the effects of temporary full-field defocus on axial length and other components of the eye, and their normalization for up to half an hour following the removal of defocus.

Methods : 15 visually-normal subjects (9 females and 6 males) of mean age 25.70 years (range 21-32) with spherical refractive error within ± 2.0 D and cylinder less than 0.75 D were enrolled in the study, confirmed with cycloplegia (Cyclopentolate 1%). 11 out of 15 subjects were of Asian ethnicity. The subjects underwent 3 separate defocus sessions under controlled conditions viewing distance tasks. For the first session, a defocus of +2.0 D was applied to the non-dominant eye with a distance refractive correction in the dominant eye with standard spectacle lenses for 2 hours (hrs). The same subjects underwent defocus sessions under controlled conditions with +3.50 D of defocus for 4 hrs, and +5.0D of defocus for 6 hrs, each after washout periods. Data collection for these two sessions is ongoing, including analysis of choroidal thickness measurements obtained from Heidelberg SD-OCT with EDI, which will be presented. The abstract deals with the first defocus session with only the non-dominant eye defocused by +2.0D. Axial length was measured with a Lenstar APS 900 from Haag-Streit Holding before the defocus sessions, immediately after, and twice after in a 15-minute interval.

Results : The mean percent increase of axial length relative to the baseline following defocus for the test eyes was +0.004% with a SD of 0.05, and it was +0.03% (SD ± 0.05) for the control eyes with rank-sum test significant at p<0.05. The coefficient of determination (r2) for the percent increase from baseline was 0.35 when the test eyes were plotted against control eyes immediately following defocus, which increased to 0.78 with p<0.01 after half an hour following defocus.

Conclusions : Percent increase in axial length from the baseline was smaller for the test eyes relative to the control eyes after 2 hours of full-field defocus. The correlation of change was normalized after half an hour following the removal of defocus. Growth signals generated by myopic defocus may reduce the axial length by attenuating its increase driven by diurnal rhythms, and could be of significant utility in myopia control strategies.