Factors influencing positive serological screening for viral diseases in Eye Bank corneal tissues
Author Affiliations & Notes
  • Jaime Juarez
    University of Sydney, Sydney, New South Wales, Australia
    New South Wales Tissue Banks, Sydney, New South Wales, Australia
  • Pierre Georges
    New South Wales Tissue Banks, Sydney, New South Wales, Australia
  • Christopher Hodge
    New South Wales Tissue Banks, Sydney, New South Wales, Australia
  • Jane Treloggen
    New South Wales Tissue Banks, Sydney, New South Wales, Australia
  • Constantinos Petsoglou
    New South Wales Tissue Banks, Sydney, New South Wales, Australia
    Save Sight Institute, Sydney, New South Wales, Australia
  • Meidong Zhu
    New South Wales Tissue Banks, Sydney, New South Wales, Australia
    Save Sight Institute, Sydney, New South Wales, Australia
  • Footnotes
    Commercial Relationships   Jaime Juarez, None; Pierre Georges, None; Christopher Hodge, None; Jane Treloggen, None; Constantinos Petsoglou, None; Meidong Zhu, None
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science June 2020, Vol.61, 4898. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Jaime Juarez, Pierre Georges, Christopher Hodge, Jane Treloggen, Constantinos Petsoglou, Meidong Zhu; Factors influencing positive serological screening for viral diseases in Eye Bank corneal tissues. Invest. Ophthalmol. Vis. Sci. 2020;61(7):4898.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : Corneas screened positive for viral serology are unable to be used for clinical transplantation. By identifying factors which may lead to false positive results, we may be able to avoid those factors and maximise usage of donated corneal tissues.

Methods : Donor corneas stored in organ culture medium at the New South Wales Tissue Banks between March 7, 2005 and March 20, 2018 were reviewed retrospectively.

Donor suitability was determined with a thorough medical history review prior to retrieval. Post mortem blood samples were collected at the time of eye retrieval within 24 hours from circulatory standstill. Corneas were screened with enzyme-linked immunosorbent assay for hepatitis B surface antigen (HBsAg), hepatitis C antibodies (HCAb) and human immunodeficiency virus 1 and 2 antibodies (HIV1+2Ab). Positive screen results were further confirmed with polymerase chain reaction or nucleic acid testing, and categorised as either true positive (TP), false positive (FP) or not tested. c2 test was used to assess the association between pre or post mortem sampling, haemolysis level and interval from circulatory standstill to enucleation (ICSE).

Results : A total of 5124 corneas were collected. 178 (3.5%) corneas were unable to be used for transplantation due to positive screening for HBsAg, HCAb and HIV1+2. Of the 144 (89%) corneas that underwent confirmatory tests, 61% were post-mortem samples. There were 63 corneas positive for HBsAg, with 11 TP and 32 FP (74%) after confirmatory testing. In the HCAb group 67 corneas were positive, with 33 TP and 24 FP (42%). Of 48 corneas positive for HIVAb1+2, 5 were TP and 39 FP (92%).

Pre or post mortem blood sampling was found to be statistically significant in predicting false positives for Hep B (p = 0.004) but not for Hep C (p = 0.573) or HIV (p = 0.387). In addition, haemolysis level was significantly related to false positives for Hep B (p = 0.027) but ICSE did not show a relationship (p = 0.706).

Conclusions : The high false positive results in HBsAg (74%) and HIV1+2 (92%) groups should be addressed. The pre or post sample types and haemolysis level impacts on false positive serology while ICSE does not contribute to false positive results. These finding may suggest that the 24 hour ICSE is meeting sample test criteria and tissue banks should consider using pre-mortem blood sample when it is available.