Investigative Ophthalmology & Visual Science Cover Image for Volume 61, Issue 9
July 2020
Volume 61, Issue 9
Free
ARVO Imaging in the Eye Conference Abstract  |   July 2020
A machine learning method for optical coherence tomography scan quality assessment
Author Affiliations & Notes
  • Shereen Elezaby
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Homayoun Bagherinia
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Hugang Ren
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Patricia Sha
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Laura Tracewell
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Charles Wu
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Ali Fard
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Mary Durbin
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Footnotes
    Commercial Relationships   Shereen Elezaby, Carl Zeiss Meditec, Inc. (E); Homayoun Bagherinia, Carl Zeiss Meditec, Inc. (E); Hugang Ren, Carl Zeiss Meditec, Inc. (E); Patricia Sha, Carl Zeiss Meditec, Inc. (E); Laura Tracewell, Carl Zeiss Meditec, Inc. (C); Charles Wu, Carl Zeiss Meditec, Inc. (C); Ali Fard, Carl Zeiss Meditec, Inc. (E); Mary Durbin, Carl Zeiss Meditec, Inc. (E)
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science July 2020, Vol.61, PB0090. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Shereen Elezaby, Homayoun Bagherinia, Hugang Ren, Patricia Sha, Laura Tracewell, Charles Wu, Ali Fard, Mary Durbin; A machine learning method for optical coherence tomography scan quality assessment. Invest. Ophthalmol. Vis. Sci. 2020;61(9):PB0090.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : The reliability of automated analysis of optical coherence tomography (OCT) scans depends on the scan quality. Quality indicators in commercial instruments only provide an overall score and do not provide localized information. Here we demonstrated a quality map using a semi-supervised machine learning technique which can aid with identifying local areas of poor quality.

Methods : Our method first computes a set of feature maps using signal strength, signal-to-noise ratio (SNR), and contrast for individual or a group of neighboring A-scans of 580 6x6x2mm OCT volumes with good and poor quality (Fig 1A shows one volume). It then combines the feature maps into a joint probability map. Then, it generates groups of likelihood functions as inference models for the feature maps using a series of thresholds (0.1 to 0.5) on the joint probability map (Fig 1B shows one group). The quality map of a volume is generated using a posterior probability for each inference model (Fig 1C). The quality score for each B-scan is calculated by averaging a quality map along the fast B-scan. To select the best inference model, we used B-scans acquired using CIRRUSTM HD-OCT 5000 (ZEISS, Dublin, CA) along with their corresponding B-scan quality scores and quality grading (performed by clinical experts) to compute receiver operating curves (ROC) (Fig 1D). Finally, the inference model with greatest area under the curve (AUC) was selected as the best inference model. A B-scan quality indicator threshold (0.3) was determined using a defined sensitivity (0.85) and specificity (0.9) on the ROC associated with the chosen inference model.

Results : Performance of the algorithm was evaluated using 481 B-scans of different quality but of the same scan type as the training data. Fig. 2 shows color-coded quality maps (red: highest quality, blue: lowest quality) and examples of OCT B-scans extracted from the volume. The sensitivity and specificity were found to be 0.89 and 0.84, respectively.

Conclusions : We demonstrated a new OCT scan quality assessment approach based on a semi-supervised machine learning method that yields a comprehensive quality map - an essential tool prior to OCT data analysis.

This is a 2020 Imaging in the Eye Conference abstract.

 

Fig 1. (A) A joint probability map from OCT volume; (B) Likelihood functions from feature maps; (C) Quality map from feature maps and the likelihood functions; (D) ROCs using three inference models.

Fig 1. (A) A joint probability map from OCT volume; (B) Likelihood functions from feature maps; (C) Quality map from feature maps and the likelihood functions; (D) ROCs using three inference models.

 