Clinical Observation of Allergic Conjunctival Diseases with Portable and Recordable Slit-Lump Device
Author Affiliations & Notes
  • HIROYUKI YAZU
    Ophthalmology, Tsurumi Daigaku Tsurumi Daigaku Tanki Daigakubu, Yokohama, Kanagawa, Japan
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Eisuke Shimizu
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Shinri Sato
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Naohiko Aketa
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Taiichiro Katayama
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Kazumi Fukagawa
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Yoko Ogawa
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Kazuo Tsubota
    Ophthalmology, Keio Gijuku Daigaku, Shinjuku-ku, Tokyo, Japan
  • Hiroshi Fujishima
    Ophthalmology, Tsurumi Daigaku Tsurumi Daigaku Tanki Daigakubu, Yokohama, Kanagawa, Japan
  • Footnotes
    Commercial Relationships   HIROYUKI YAZU, OUI Inc (P); Eisuke Shimizu, OUI Inc (P); Shinri Sato, None; Naohiko Aketa, OUI Inc (P); Taiichiro Katayama, None; Kazumi Fukagawa, None; Yoko Ogawa, None; Kazuo Tsubota, None; Hiroshi Fujishima, Alcon Laboratories, Inc (F), Allergan, Inc (F), Kobayashi Pharmaceutical Co., Ltd (F), Otsuka Pharmaceutical Co., Ltd (F), Santen, Pharmaceutical Co., Ltd (F), Senju Pharmaceutical Co., Ltd (F), White Medical Co., Ltd (F)
  • Footnotes
    Support  CASIO SCIENCE PROMOTION FOUNDATION, THE JAPAN AGENCY FOR MEDICAL RESEARCH AND DEVELOPMENT, UEHARA MEMORIAL FOUNDATION, HITACHI GLOBAL FOUNDATION, KONDO MEMORIAL FOUNDATION, EUSTYLELAB
Investigative Ophthalmology & Visual Science June 2021, Vol.62, 379. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      HIROYUKI YAZU, Eisuke Shimizu, Shinri Sato, Naohiko Aketa, Taiichiro Katayama, Kazumi Fukagawa, Yoko Ogawa, Kazuo Tsubota, Hiroshi Fujishima; Clinical Observation of Allergic Conjunctival Diseases with Portable and Recordable Slit-Lump Device. Invest. Ophthalmol. Vis. Sci. 2021;62(8):379.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : Not only ophthalmologists but also non-ophthalmologists often prescribe eye drops for allergic conjunctivital diseases (ACDs); however, there are many cases that are treated without sufficient examination and diagnosis of the eyes. We have invented a portable, recordable, and smartphone-attachable slit-lamp device, called the Smart Eye Camera (SEC). The purpose of this study was to compare the diagnostic abilities of ACDs between the SEC and the conventional, non-portable slit-lamp microscope.

Methods : This prospective observational study included thirty-two eyes of 17 Japanese patients (mean age: 21.5±14.8 years; range: 11-51 years; female: 5). The severity of ten objective signs in the palpebral conjunctiva, bulbar conjunctiva, limbus and cornea were scored on a grading scale of 0 to 4 (0 = normal; 1+ = mild; 2+ = moderate; 3+ = severe), respectively. First, two ophthalmologists used the conventional slit-lamp microscope to examine the grade of the ACDs. Second, another ophthalmologist filmed the eyes in video mode by the SEC and two other ophthalmologists evaluated the grades on another day. The correlation and inter-rater reproducibility in total scores of ten objective signs among two devices were determined.

Results : Total scores of clinical signs evaluated by the two approaches showed a strong correlation with statistical significance (both eyes: r = 0.918 [95%CI: 0.839 to 0.959; p < 0.001]). Inter-rater agreement was substantial (weighted κ value = 0.631 [95%CI: 0.601 to 0.661; p < 0.001]).

Conclusions : This study suggests that the SEC is as reliable as the conventional non-portable slit-lamp microscope for evaluating ACDs.