Direct comparison of photoreceptor reflectivity measurements using simultaneous adaptive optics SLO and OCT
Author Affiliations & Notes
  • Andrew J. Bower
    National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
  • Tao Liu
    National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
  • Zhuolin Liu
    Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, United States
  • Nancy Aguilera
    National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
  • Joanne Li
    National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
  • Rongwen Lu
    National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
  • John Giannini
    National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
  • Steven Cornelissen
    Boston Micromachines Corporation, Cambridge, Massachusetts, United States
  • Alfredo Dubra
    Department of Ophthalmology, Stanford University, Palo Alto, California, United States
  • Daniel Hammer
    Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, United States
  • Johnny Tam
    National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
  • Footnotes
    Commercial Relationships   Andrew Bower, None; Tao Liu, None; Zhuolin Liu, Indiana University (P); Nancy Aguilera, None; Joanne Li, None; Rongwen Lu, None; John Giannini, None; Steven Cornelissen, None; Alfredo Dubra, None; Daniel Hammer, None; Johnny Tam, None
  • Footnotes
    Support  Intramural Research Program of the National Eye Institute, National Institutes of Health
Investigative Ophthalmology & Visual Science June 2021, Vol.62, 26. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Andrew J. Bower, Tao Liu, Zhuolin Liu, Nancy Aguilera, Joanne Li, Rongwen Lu, John Giannini, Steven Cornelissen, Alfredo Dubra, Daniel Hammer, Johnny Tam; Direct comparison of photoreceptor reflectivity measurements using simultaneous adaptive optics SLO and OCT. Invest. Ophthalmol. Vis. Sci. 2021;62(8):26.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To investigate the similarities and differences in reflectivity of individual cone photoreceptors as seen by adaptive optics (AO) scanning light ophthalmoscopy (AO-SLO) in comparison to AO-optical coherence tomography (AO-OCT).

Methods : Simultaneous, co-registered AO-SLO and AO-OCT images unaffected by transverse or longitudinal chromatic aberration were acquired from three subjects at eccentricities from 2.5° to 10° temporal. Images were acquired using a custom multimodal AO ophthalmoscope in which 10% of the 1080 nm light returning from the eye was captured for AO-SLO using a custom-developed avalanche photodiode (Boston Micromachines), with the remaining 90% of 1080 nm light used for AO-OCT. Following manual identification of photoreceptors, the following measurements corresponding to single cones were extracted: (1) AO-SLO intensity, (2) AO-OCT inner segment/outer segment (IS/OS) junction intensity, (3) AO-OCT cone outer segment tip (COST) intensity, and (4) AO-OCT outer segment projection intensity. In addition, outer segment length was measured as the intensity peak-to-peak distance between the IS/OS and COST of each cone.

Results : The variable reflectivity observed in the cone photoreceptor mosaic matched well between the AO-SLO and AO-OCT projection images. AO-SLO intensities of 500 cones identified in the images were significantly correlated with outer segment projection intensity in AO-OCT (p<0.01, F-test on linear regression), with stronger correspondence of the AO-SLO intensity to IS/OS intensity compared to COST intensity. Both the IS/OS and COST layers could be observed in 91% of cones. In the remaining 9% of cones, only a single reflection in the IS/OS was observed with no apparent corresponding COST reflection. When both IS/OS and COST reflections were observed, the IS/OS reflection was brighter for 88% of cones. There was no apparent relationship between AO-SLO reflectivity and outer segment length (p>0.01, F-test on linear regression).

Conclusions : The use of a shared 1080 nm light source for simultaneous acquisition of AO-SLO images and AO-OCT volumes enables direct comparison of cone reflectivity across two inherently co-registered modalities. We show that cone reflectance on AO-SLO images arises more strongly from the IS/OS band, which may have implications for our understanding of cone waveguiding properties and their disc shedding processes.