June 2021
Volume 62, Issue 8
Open Access
ARVO Annual Meeting Abstract  |   June 2021
Association Between Alzheimer’s Disease and Artificial Intelligence-based Glaucomatous Optic Neuropathy Score
Author Affiliations & Notes
  • Anran RAN
    Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, Hong Kong
  • Christopher L. Chen
    Department of Pharmacology, National University of Singapore, Singapore, Singapore
  • Xi Wang
    Computer Science and Engineering, The Chinese University of Hong Kong, Hong Kong, Hong Kong
  • Vincent Mok
    Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Hong Kong, Hong Kong
  • Clement C. Tham
    Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, Hong Kong
  • Tien Y Wong
    Singapore Eye Research Institute, Singapore, Singapore
  • Carol Yim-lui Cheung
    Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, Hong Kong
  • Footnotes
    Commercial Relationships   Anran RAN, None; Christopher L. Chen, None; Xi Wang, None; Vincent Mok, None; Clement C. Tham, None; Tien Wong, None; Carol Cheung, None
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science June 2021, Vol.62, 2121. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Anran RAN, Christopher L. Chen, Xi Wang, Vincent Mok, Clement C. Tham, Tien Y Wong, Carol Yim-lui Cheung; Association Between Alzheimer’s Disease and Artificial Intelligence-based Glaucomatous Optic Neuropathy Score. Invest. Ophthalmol. Vis. Sci. 2021;62(8):2121.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : The associations between Alzheimer’s disease (AD) and glaucoma are inconsistent in the current literature. We aim to assess the association between AD and glaucomatous optic neuropathy (GON) using artificial intelligence (AI) predicted continuous scores from optical coherence tomography (OCT) volumetric scans.

Methods : This study included 2,269 volumetric optic disc OCT scans measured with Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA) from 440 eyes of 233 AD subjects and 1,158 OCT scans from 271 eyes of 136 cognitively normal subjects. GON score was calculated from each OCT scan using a validated AI deep-learning algorithm. GON score was a continuous variable ranged from 0 to 1, and a more significant score represented a higher probability of GON. In addition, average and quadratic retinal nerve fiber layer (RNFL) thicknesses were also extracted from the OCT device.

Results : There was no significant difference in AI-based GON scores between AD and cognitively normal subjects (0.28 ± 0.31 vs. 0.30 ± 0.33, p = 0.20). However, AD subjects had significant thinner RNFL average (85.97 ± 17.65 μm vs. 90.35 ± 13.71 μm, p < 0.001), temporal (67.39 ± 17.02 μm vs. 74.31 ± 21.35 μm, p < 0.001), nasal (66.06 ± 15.28 μm vs. 67.68 ± 12.12 μm, p = 0.002), inferior (106.46 ± 29.58 μm vs. 112.54 ± 23.91 μm, p < 0.001) and superior (103.96 ± 25.79 μm vs. 106.86 ± 21.31 μm, p = 0.001) thicknesses. A simple linear regression test showed that the association between AD and AI-based GON scores was insignificant (p = 0.199). GON score is equal to 0.297-0.015x(diagnosis) when diagnosis is 1 (AD) or 0 (normal). Pearson’s correlation showed that GON scores had moderate and inverse correlation with RNFL average (R = -0.524, p < 0.001), superior (R = -0.495, p < 0.001), and inferior (R = -0.556, p < 0.001) thickness, as well as weak and inverse correlation with RNFL temporal (R = -0.210, p = 0.001) and nasal (R = -0.220, p < 0.001) thickness. AD was only weakly and inversely associated with RNFL average (R = -0.125, p < 0.001), temporal (R = -0.174, p < 0.001), and inferior (R = -0.103, p < 0.001) thicknesses.

Conclusions : Although AD subjects had thinner RNFL thickness than cognitively normal subjects, AD is not associated with AI-based GON score. Further research is still warranted to confirm the null association between AD and GON.

This is a 2021 ARVO Annual Meeting abstract.

 

An example of OCT volumetric scan predicted as GON by the AI algorithm.

An example of OCT volumetric scan predicted as GON by the AI algorithm.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×