August 2021
Volume 62, Issue 11
Open Access
ARVO Imaging in the Eye Conference Abstract  |   August 2021
Increasing patient and operator protection when using ophthalmic diagnostic devices during the COVID-19 pandemic
Author Affiliations & Notes
  • Jochen Straub
    Carl Zeiss Meditec, Inc., California, United States
  • Sachin Sinha
    Carl Zeiss Meditec, Inc., California, United States
  • Tim Surber
    Carl Zeiss Meditec, Inc., California, United States
  • Robert Bourque
    Carl Zeiss Meditec, Inc., California, United States
  • Ashwini Tamhankar
    Carl Zeiss Meditec, Inc., California, United States
  • Katharina Foote
    Carl Zeiss Meditec, Inc., California, United States
  • Thomas Callan
    Carl Zeiss Meditec, Inc., California, United States
  • Gary Lee
    Carl Zeiss Meditec, Inc., California, United States
  • Eric Larson
    Carl Zeiss Meditec, Inc., California, United States
  • Kique Romero
    Carl Zeiss Meditec, Inc., California, United States
  • Robert Sprowl
    Carl Zeiss Meditec, Inc., California, United States
  • Amelie Koch
    Carl Zeiss Meditec, Inc., California, United States
  • Pranav Malvania
    Carl Zeiss Meditec, Inc., California, United States
  • Jose Castanon
    Carl Zeiss Meditec, Inc., California, United States
  • Patty Seiden
    Carl Zeiss Meditec, Inc., California, United States
  • Jochen Tham
    Carl Zeiss Meditec AG Oberkochen, Oberkochen, Baden-Württemberg, Germany
  • Footnotes
    Commercial Relationships   Jochen Straub, Carl Zeiss Meditec, Inc. (E); Sachin Sinha, Carl Zeiss Meditec, Inc. (E); Tim Surber, Carl Zeiss Meditec, Inc. (E); Robert Bourque, Carl Zeiss Meditec, Inc. (E); Ashwini Tamhankar, Carl Zeiss Meditec, Inc. (E); Katharina Foote, Carl Zeiss Meditec, Inc. (E); Thomas Callan, Carl Zeiss Meditec, Inc. (E); Gary Lee, Carl Zeiss Meditec, Inc. (E); Eric Larson, Carl Zeiss Meditec, Inc. (E); Kique Romero, Carl Zeiss Meditec, Inc. (E); Robert Sprowl, Carl Zeiss Meditec, Inc. (E); Amelie Koch, Carl Zeiss Meditec, Inc. (E); Pranav Malvania, Carl Zeiss Meditec, Inc. (E); Jose Castanon, Carl Zeiss Meditec, Inc. (E); Patty Seiden, Carl Zeiss Meditec, Inc. (E); Jochen Tham, Carl Zeiss Meditec AG (E)
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science August 2021, Vol.62, 35. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Jochen Straub, Sachin Sinha, Tim Surber, Robert Bourque, Ashwini Tamhankar, Katharina Foote, Thomas Callan, Gary Lee, Eric Larson, Kique Romero, Robert Sprowl, Amelie Koch, Pranav Malvania, Jose Castanon, Patty Seiden, Jochen Tham; Increasing patient and operator protection when using ophthalmic diagnostic devices during the COVID-19 pandemic. Invest. Ophthalmol. Vis. Sci. 2021;62(11):35.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : Ophthalmic diagnostic devices require patient and operator to be physically close during the exam. Goal of this study is to develop and release protective measures to increase patient and operator protection during COVID-19.

Methods : We applied recommendations by the World Health Organization (WHO), the Center of Disease Control (CDC) and the Environmental Protection Agency (EPA) to the situation in the ophthalmic exam room, and developed, released, distributed, and communicated the resulting protective measures. We report the number of website visits, document downloads, and parts distributed from March 2020 through February 2021.

Results : Detailed instructions on remote control of ophthalmic devices using remote desktop software or extension on monitors were published, viewed 4,450 and downloaded 1,014 times.
Custom breath shields separating operator and patient were developed and a total of 82,827 have been shipped, free of charge or at-cost. Third party order information for single-use plastic bags and dental barrier film that fit ophthalmic devices and can cover high touch surfaces has been published on a dedicated web page.
All cleaning instructions have been published in one place (viewed 25,819 times, downloaded 11,781 times). Highly accelerated lifetime tests were performed to confirm that frequent cleaning and disinfection of the HFA bowl with a spray of atomized isopropyl alcohol will not damage or alter the performance of the bowl. Updated disinfection instructions have been published and downloaded 8,318 times. An additional highly accelerated lifetime test has shown that the bowl inside the HFA can be disinfected using UV-C radiation without damaging the functionality of the perimeter.

Conclusions : In response to the COVID-19 pandemic, we have provided improved cleaning instructions for the HFA family of bowl perimeters, have developed and distributed over 80,000 breath shields, have identified protective coverings for high-touch areas, and have developed and communicated different ways to operate existing devices remotely. While we have not been able to quantify the effectiveness of the individual measures, it is our assumption that implementing these measures which are based on recommendations by the WHO, the CDC, and the EPA, have increased patient and operator protection.

This is a 2021 Imaging in the Eye Conference abstract.

 

Illustration of protective measures.

Illustration of protective measures.

 

Website visits, document downloads, and parts distributed.

Website visits, document downloads, and parts distributed.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×