June 2022
Volume 63, Issue 7
Open Access
ARVO Annual Meeting Abstract  |   June 2022
Suprachoroidal Retinal prostheses, longterm stability and safety results.
Author Affiliations & Notes
  • Penelope J Allen
    Bionic Eye Unit, Centre for Eye Research Australia Ltd, East Melbourne, Victoria, Australia
    Surgery ( Ophthalmology), University of Melbourne Faculty of Dentistry, Medicine and Health Sciences, Parkville, Victoria, Australia
  • Carla J Abbott
    Bionic Eye Unit, Centre for Eye Research Australia Ltd, East Melbourne, Victoria, Australia
    Surgery ( Ophthalmology), University of Melbourne Faculty of Dentistry, Medicine and Health Sciences, Parkville, Victoria, Australia
  • Maria Kolic
    Bionic Eye Unit, Centre for Eye Research Australia Ltd, East Melbourne, Victoria, Australia
  • Elizabeth Baglin
    Bionic Eye Unit, Centre for Eye Research Australia Ltd, East Melbourne, Victoria, Australia
  • David AX Nayagam
    Bionics Institute, East Melbourne, Victoria, Australia
    The University of Melbourne Department of Clinical Pathology, Melbourne, Victoria, Australia
  • Stephanie Epp
    Bionics Institute, East Melbourne, Victoria, Australia
  • Nicholas Barnes
    Research School of Electrical, Energy and Mechanical Engineering, the Australian National University, Canberra, Victoria, Australia
  • Chi D Luu
    Surgery ( Ophthalmology), University of Melbourne Faculty of Dentistry, Medicine and Health Sciences, Parkville, Victoria, Australia
    Bionic Eye Unit, Centre for Eye Research Australia Ltd, East Melbourne, Victoria, Australia
  • Robert Briggs
    The University of Melbourne, Department of Surgery (Otolaryngology), Melbourne, Victoria, Australia
  • Jonathan Yeoh
    Bionic Eye Unit, Centre for Eye Research Australia Ltd, East Melbourne, Victoria, Australia
  • William Kentler
    School of Engineering, University of Melbourne, Melbourne, Victoria, Australia
  • Samuel Titchener
    Bionics Institute, East Melbourne, Victoria, Australia
  • Christopher E Williams
    Bionics Institute, East Melbourne, Victoria, Australia
  • Matthew Petoe
    Bionics Institute, East Melbourne, Victoria, Australia
  • Footnotes
    Commercial Relationships   Penelope Allen BVT, Code F (Financial Support), CERA, Code P (Patent); Carla Abbott BVT, Code F (Financial Support); Maria Kolic BVT, Code F (Financial Support); Elizabeth Baglin BVT, Code F (Financial Support); David Nayagam BVT, Code F (Financial Support), Bionics Institute, Code P (Patent); Stephanie Epp BVT, Code F (Financial Support); Nicholas Barnes BVT, Code F (Financial Support), ANU, Code P (Patent); Chi Luu BVT, Code F (Financial Support); Robert Briggs BVT, Code F (Financial Support); Jonathan Yeoh BVT, Code F (Financial Support); William Kentler BVT, Code F (Financial Support); Samuel Titchener BVT, Code F (Financial Support); Christopher Williams BVT, Code F (Financial Support), Bionics Insitute, Code P (Patent); Matthew Petoe BVT, Code F (Financial Support), Bionics Insitute, Code P (Patent)
  • Footnotes
    Support  ARC Special Research Initiative in Bionic Vision Science and Technology grant to Bionic Vision Australia (BVA). NHMRC grant 1082358. Operations Infrastructure support from the Victorian State Government to CERA and the Bionics Institute.
Investigative Ophthalmology & Visual Science June 2022, Vol.63, 1863. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Penelope J Allen, Carla J Abbott, Maria Kolic, Elizabeth Baglin, David AX Nayagam, Stephanie Epp, Nicholas Barnes, Chi D Luu, Robert Briggs, Jonathan Yeoh, William Kentler, Samuel Titchener, Christopher E Williams, Matthew Petoe; Suprachoroidal Retinal prostheses, longterm stability and safety results.. Invest. Ophthalmol. Vis. Sci. 2022;63(7):1863.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To report the longterm safety and stability of two suprachoroidal retinal prosthesis trials (NCT01603576, NCT03406416), comprising of seven patients, with followup ranging from two to nine years.

Methods : Three patients with retinitis pigmentosa were implanted with our prototype 24 channel suprachoroidal retinal prosthesis in May - August 2012. One patient had the entire device removed following the trial in 2014 for a medical reason unrelated to the device. The other two patients had the intraocular array left in situ and the percutaneous connector removed, as planned. Ocular followup has continued since that time, albeit interrupted due to the Covid 19 pandemic.
Four patients with retinitis pigmentosa were implanted with our second generation 44 channel fully implantable device in February to August 2018. They continue to use the device in the home enviroment.
Ocular assessments including clinical examination, colour fundus photographs and optical coherence tomography (OCT) have been used to assess stability of the devices and retinal health longitudinally in patients (P) 1-7.

Results : Electrode to retina distance OCT measurements over two to nine years, calculated by comparing group means, showed an increase over time. (Wilcoxon, p=0.03) In the prototype trial, the increase appeared linked to fibrosis and stimulation, with no progression once devices were inactivated, in the second generation trial, it seemed primarily due to passive fibrosis.
Retinal thickness OCT measurements showed a slow reduction in central retinal thickness, as expected, due to progression of dystrophic disease. (Wilcoxon, p=0.11)
Device position compared to the optic nerve head (ONH) was calculated and three patients demonstrated some temporal movement. P1 position returned to baseline over seven years, P2 stabilised over three months and P6 had a temporary choroidal effusion event which settled spontaneously.
Function of the four Generation two fully implantable devices remains stable.

Conclusions : Using fundus photography and OCT measurements we demonstrate that retinal prostheses implanted in the suprachoroidal space for up to nine years are overall stable in position and cause mild progressive fibrosis in the suprachoroidal space. Longterm assessment of the changes in the retina are all consistent with the underlying retinal dystrophy.
This provides further evidence of the safety of the suprachoroidal surgical approach for retinal prostheses.

This abstract was presented at the 2022 ARVO Annual Meeting, held in Denver, CO, May 1-4, 2022, and virtually.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×