June 2022
Volume 63, Issue 7
Open Access
ARVO Annual Meeting Abstract  |   June 2022
Reliability of Quantitative Autofluorescence Imaging in a Multicenter Study Involving Patients with Stargardt Disease
Author Affiliations & Notes
  • Jeroen Adrianus Antonius Hendrikus Pas
    Radboudumc Afdeling Oogheelkunde, Nijmegen, Gelderland, Netherlands
    Radboud Universiteit Donders Institute for Brain Cognition and Behaviour, Nijmegen, Gelderland, Netherlands
  • Patty P.A. Dhooge
    Radboudumc Afdeling Oogheelkunde, Nijmegen, Gelderland, Netherlands
    Radboud Universiteit Donders Institute for Brain Cognition and Behaviour, Nijmegen, Gelderland, Netherlands
  • Philipp T. Möller
    Department of Ophthalmology, Rheinische Friedrich-Wilhelms-Universitat Bonn, Bonn, Nordrhein-Westfalen, Germany
    GRADE Reading Center, Bonn, Germany
  • Katarina Stingl
    University Eye hospital, Center for Ophthalmology, University of Tuebingen, Germany
  • Camiel J F Boon
    Department of Ophthalmology, Leids Universitair Medisch Centrum, Leiden, Zuid-Holland, Netherlands
    Department of Ophthalmology, Amsterdam Universitair Medische Centra, Amsterdam, Noord-Holland, Netherlands
  • Andrew J Lotery
    Department of Ophthalmology, University of Southampton, Southampton, Hampshire, United Kingdom
  • Maurizio Battaglia Parodi
    Department of Ophthalmology, IRCCS Ospedale San Raffaele, Milano, Lombardia, Italy
  • Philipp Herrmann
    Department of Ophthalmology, Rheinische Friedrich-Wilhelms-Universitat Bonn, Bonn, Nordrhein-Westfalen, Germany
    Center for Rare Diseases Bonn (ZSEB), Rheinische Friedrich-Wilhelms-Universitat Bonn, Bonn, Nordrhein-Westfalen, Germany
  • Wolfgang Klein
    Katairo GmbH, Kusterdingen, Germany
  • Mario G Fsadni
    Katairo GmbH, Kusterdingen, Germany
  • Thomas H. Wheeler-Schilling
    Center for Ophthalmology and Institute for Ophthalmic Research, Eberhard Karls Universitat Tubingen, Tubingen, Baden-Württemberg, Germany
  • Frank G Holz
    Department of Ophthalmology, Rheinische Friedrich-Wilhelms-Universitat Bonn, Bonn, Nordrhein-Westfalen, Germany
    GRADE Reading Center, Bonn, Germany
  • Carel C B Hoyng
    Radboudumc Afdeling Oogheelkunde, Nijmegen, Gelderland, Netherlands
    Radboud Universiteit Donders Institute for Brain Cognition and Behaviour, Nijmegen, Gelderland, Netherlands
  • Steffen Schmitz-Valckenberg
    Department of Ophthalmology, Rheinische Friedrich-Wilhelms-Universitat Bonn, Bonn, Nordrhein-Westfalen, Germany
    GRADE Reading Center, Bonn, Germany
  • Footnotes
    Commercial Relationships   Jeroen Pas None; Patty Dhooge None; Philipp Möller None; Katarina Stingl None; Camiel Boon None; Andrew Lotery None; Maurizio Battaglia Parodi None; Philipp Herrmann None; Wolfgang Klein Katairo GmbH, Code C (Consultant/Contractor), Katairo GmbH, Code F (Financial Support), Katairo GmbH, Code I (Personal Financial Interest), Katairo GmbH, Code S (non-remunerative); Mario Fsadni paid Consultant to Katairo outworking for International Pharm-Med Ltd in UK, Code C (Consultant/Contractor); Thomas Wheeler-Schilling None; Frank Holz None; Carel Hoyng None; Steffen Schmitz-Valckenberg None
  • Footnotes
    Support  European Union’s Horizon 2020 research and innovation programme No. 779317
Investigative Ophthalmology & Visual Science June 2022, Vol.63, 4098 – F0062. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Jeroen Adrianus Antonius Hendrikus Pas, Patty P.A. Dhooge, Philipp T. Möller, Katarina Stingl, Camiel J F Boon, Andrew J Lotery, Maurizio Battaglia Parodi, Philipp Herrmann, Wolfgang Klein, Mario G Fsadni, Thomas H. Wheeler-Schilling, Frank G Holz, Carel C B Hoyng, Steffen Schmitz-Valckenberg; Reliability of Quantitative Autofluorescence Imaging in a Multicenter Study Involving Patients with Stargardt Disease. Invest. Ophthalmol. Vis. Sci. 2022;63(7):4098 – F0062.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : The aim of this study is to establish the reliability of quantitative autofluorescence (qAF) in a multicenter setting in order to validate qAF as an endpoint for interventional clinical trials in Stargardt disease (STGD1).

Methods : A total of 104 STGD1 patients (208 eyes) underwent qAF imaging at two visits (screening and baseline, mean interval 20 ± 13 days), with two qAF recordings per visit, as part of the Stargardt Remofuscin Treatment Trial (EudraCT No. 2018-001496-20) and according to standardized image acquisition protocol including operator training and certification. qAF8 values were determined by calculating the mean qAF values within the 8 middle segments of the Delori pattern. Eyes were independently graded by the concerned study site and the central reading center. Intra- and inter-visit as well as interobserver (study site versus reading center) reproducibility of qAF8 levels were obtained using intraclass correlation (ICC) and coefficient of repeatability (CR) based on the method of Bland-Altman.

Results : At the first visit, there were significant differences in qAF8 values between the six study sites (p<0.001). Overall, the mean qAF8 value at baseline, 463.55±107.81 units, was not significantly different from the value at screening in the same patients, 467.63±108.53 units (p=0.753). qAF8 reproducibility was ± 26.1% for intra-visit, ± 40.3% for inter-visit, and ± 21.6% for the interobserver reproducibility. Intra-visit and interobserver reliability of qAF8 was good to excellent for all sites (ICC of 0.84-0.99). However, we observed a significant difference of 8.80 ± 56.18 qAF8 units between both movies acquired on the same day and 17.49 ± 48.60 between observers (p=0.007 and p<0.001). Variability between visits was higher with ICC of 0.43-0.83, but there was no significant difference in the qAF8 units measured at screening and baseline (p=0.210).

Conclusions : Real-life test-retest variability of qAF is higher in the multicenter setting than previously reported in single center studies. Possible explanations include the demanding imaging protocol, operator variability and differences in patient characteristics. qAF is a successful tool to diagnose STGD1. However, when using qAF as clinical trial endpoint, increased variability must be considered, and larger sample sizes may be required to demonstrate treatment effects.

This abstract was presented at the 2022 ARVO Annual Meeting, held in Denver, CO, May 1-4, 2022, and virtually.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×