June 2022
Volume 63, Issue 7
Open Access
ARVO Annual Meeting Abstract  |   June 2022
Assessment of a machine learning approach to predict subjective sphero-cylindrical correction using wavefront aberrometry data
Author Affiliations & Notes
  • Carlos Santiago Hernandez Torres
    Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autonoma de Madrid, Madrid, Madrid, Spain
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Andrea Gil Ruiz
    Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autonoma de Madrid, Madrid, Madrid, Spain
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Ignacio Casares
    Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autonoma de Madrid, Madrid, Madrid, Spain
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Jesus Poderoso
    Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autonoma de Madrid, Madrid, Madrid, Spain
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Alec Wehse
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Shivang Dave
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Daryl Lim
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Manuel Sánchez Montañés
    Department of Computer Science, Universidad Autonoma de Madrid, Madrid, Madrid, Spain
  • Eduardo Lage Negro
    Departamento de Tecnología Electrónica y de las Comunicaciones, Universidad Autonoma de Madrid, Madrid, Madrid, Spain
    PlenOptika, Inc., Boston, MA, USA, Boston, Massachusetts, United States
  • Footnotes
    Commercial Relationships   Carlos Santiago Hernandez Torres None; Andrea Gil Ruiz None; Ignacio Casares None; Jesus Poderoso None; Alec Wehse None; Shivang Dave None; Daryl Lim None; Manuel Sánchez Montañés None; Eduardo Lage Negro None
  • Footnotes
    Support  Madrid Regional Government IND2019/TIC-17116
Investigative Ophthalmology & Visual Science June 2022, Vol.63, 175 – F0022. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Carlos Santiago Hernandez Torres, Andrea Gil Ruiz, Ignacio Casares, Jesus Poderoso, Alec Wehse, Shivang Dave, Daryl Lim, Manuel Sánchez Montañés, Eduardo Lage Negro; Assessment of a machine learning approach to predict subjective sphero-cylindrical correction using wavefront aberrometry data. Invest. Ophthalmol. Vis. Sci. 2022;63(7):175 – F0022.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : Uncorrected Refractive Errors (UREs) is a reversible condition that can be treated with appropriate eyeglasses. UREs affect over 1 billion people globally, with 90% of this population living in low-and-middle-income countries where vision exams can be highly inaccessible due to a shortage of experienced eyecare professionals. This work aims to assess if a machine learning (ML) approach, when applied to data obtained with an affordable handheld autorefractor, could increase access to clinical-quality subjective refraction (SR) when operated by non-experts.

Methods : Data used for this analysis was obtained from a clinical study performed at Aravind Eye Hospital in Madurai, India, using a low-cost portable wavefront aberrometer, an early prototype of the QuickSee (QS) (PlenOptika, Inc., USA). A total of 669 participants were enrolled with ages ranging between 15 and 70 years (35.2 ± 13.7) and spherical equivalent error between -6.0 D and 3.5 D (-0.7 ± 1.67 D). Four ML regressor models were trained and tested for each power vector M, J0 and J45: random forest (RF), gradient boosting (GB), extreme gradient boosting (XGB), and a custom assembly model (ASB) that averages the predictions of RF, GB, and XGB. Algorithms were trained on a dataset of 1,244 samples using as input features: age, gender, Zernike coefficients up to 5th order, and measurement quality related metrics provided by the autorefractor. A smaller subset of 518 unseen samples was used to test the agreement of the predictions against SR using Bland-Altman analysis, overall prediction error in terms of mean absolute error (MAE) and root mean squared error (RMSE), and the percentage of agreement for 0.25 D and 0.5 D thresholds.

Results : All models improved the agreement with SR compared to the baseline autorefraction, but ASB obtained the best results (Table 1). Bland-Altman analysis showed a decrease in the 95% limits of agreement of ±0.63 D, ±0.14 D, and ±0.08 D for M, J0 and J45, respectively. The wavefront-aberrometry related variables had the biggest impact on the prediction, while demographic and measurement quality-related features showed a heterogeneous but consistent predictive value.

Conclusions : These results suggest that ML is effective for improving precision in predicting patient’s SR from objective measurements taken with a low-cost portable device.

This abstract was presented at the 2022 ARVO Annual Meeting, held in Denver, CO, May 1-4, 2022, and virtually.

 

Agreement comparison between ML and QS with SR

Agreement comparison between ML and QS with SR

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×