June 2022
Volume 63, Issue 7
Open Access
ARVO Annual Meeting Abstract  |   June 2022
Foreground-background registration for angiography fundus images
Author Affiliations & Notes
  • Hugang Ren
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Susan Su
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Archana Kolli
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Neil D'Souza
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Niranchana Manivannan
    Carl Zeiss Meditec, Inc., Dublin, California, United States
  • Footnotes
    Commercial Relationships   Hugang Ren Carl Zeiss Meditec, Inc., Code E (Employment); Susan Su Carl Zeiss Meditec, Inc., Code E (Employment); Archana Kolli Carl Zeiss Meditec, Inc., Code E (Employment); Neil D'Souza Carl Zeiss Meditec, Inc., Code E (Employment); Niranchana Manivannan Carl Zeiss Meditec, Inc., Code E (Employment)
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science June 2022, Vol.63, 241 – F0088. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Hugang Ren, Susan Su, Archana Kolli, Neil D'Souza, Niranchana Manivannan; Foreground-background registration for angiography fundus images. Invest. Ophthalmol. Vis. Sci. 2022;63(7):241 – F0088.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : The predominant descriptive features of fundus images are the retinal vessels. The performance of a registration algorithm when applied to the fundus angiography images is often not optimal due to the poor contrast of retinal vessels in the early stages of angiography. In this research, we propose a weighted foreground-background registration (FBR) method to improve the performance.

Methods : The workflow of the proposed method is shown in Figure 1. Retinal vessels images (RVI) are detected using first-order derivative of the Gaussian filter in image pairs. Registration is applied in two steps. 1) Coarse registration: Harris corner detection is applied to RVI pairs followed by non-maximal suppression. Feature point matching is done between the RVI pairs and the transformation is applied to form a coarse registered image. 2) Fine registration: Retinal background image (RBI) is computed for the coarse registered image pairs by eliminating the retinal vessels and applying contrast limited adaptive histogram equalization (CLAHE) for simultaneous noise reduction and contrast enhancement. Feature point matching is done between the RBI pairs and the transformation is applied to form a fine registered image.

Fluorescein angiography image sequences from 22 eyes (5 healthy and 17 subjects with various retinal pathologies) were acquired using CLARUSTM 700 (ZEISS, Dublin, CA). Three image pairs from each of the eyes were randomly selected (1 image pair each from early, mid, and late phases) and six landmarks were labeled for each pair of the images [1]. The angular distance between the landmarks in the registered images should be minimal for ideal registration. The mean angular distance (MAD) with and without FBR was calculated for the quantitative evaluation.

Results : Table 1 shows the MAD for image pairs from different angiography phases. With FBR, the performance of the registration is improved by 9.5% in early phase and 7.1% in late phase. In the mid phase, the performance doesn’t show any improvement with FBR.

Conclusions : The proposed FBR algorithm may improve the registration in early and late phase angiography images by augmenting the feature point matching of retinal vessels with histogram equalized background information.

Reference:
[1] Manivannan et al. IOVS 2021; 62(8):1794.

This abstract was presented at the 2022 ARVO Annual Meeting, held in Denver, CO, May 1-4, 2022, and virtually.

 

Figure1. Workflow of the FBR registration

Figure1. Workflow of the FBR registration

 

Table1. Summary of MAD for different angiography phases