ARVO Annual Meeting Abstract  |   June 2023
Evaluation of the Temporal Anterior Chamber Depth Measured with Anterior Segment Swept-Source Optical Coherence Tomography and its Association with the Van-Herick Test and Angle Measurements
Author Affiliations & Notes
  • Fabio Lavinsky
    Medical School, Universidade do Vale do Rio dos Sinos, Sao Leopoldo, RS, Brazil
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Ariadne Peres Silva Swarovsky
    Medical School, Universidade do Vale do Rio dos Sinos, Sao Leopoldo, RS, Brazil
  • Rodrigo Leivas Lindenmeyer
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Rafaela Correa Meyer Campos de Almeida
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Anais da Silva
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Gustavo Afonso Santiago Gomes
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Daniel Lavinsky
    Ophthalmology, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Victoria dAzevedo Silveira
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Monica Oliveira
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
  • Jaco Lavinsky
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
    Ophthalmology, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
  • Egidio Picceti
    Ophthalmology, Grupo Hospitalar Conceicao, Porto Alegre, Rio Grande do Sul, Brazil
  • Helena Messinger Pakter
    Ophthalmology, Hospital de Clinicas de Porto Alegre, Porto Alegre, RS, Brazil
    Ophthalmology, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil
  • Footnotes
    Commercial Relationships   Fabio Lavinsky None; Ariadne Swarovsky None; Rodrigo Lindenmeyer None; Rafaela Almeida None; Anais da Silva None; Gustavo Gomes None; Daniel Lavinsky None; Victoria Silveira None; Monica Oliveira None; Jaco Lavinsky None; Egidio Picceti None; Helena Pakter None
  • Footnotes
    Support  None
Investigative Ophthalmology & Visual Science June 2023, Vol.64, 1363. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Fabio Lavinsky, Ariadne Peres Silva Swarovsky, Rodrigo Leivas Lindenmeyer, Rafaela Correa Meyer Campos de Almeida, Anais da Silva, Gustavo Afonso Santiago Gomes, Daniel Lavinsky, Victoria dAzevedo Silveira, Monica Oliveira, Jaco Lavinsky, Egidio Picceti, Helena Messinger Pakter; Evaluation of the Temporal Anterior Chamber Depth Measured with Anterior Segment Swept-Source Optical Coherence Tomography and its Association with the Van-Herick Test and Angle Measurements. Invest. Ophthalmol. Vis. Sci. 2023;64(8):1363.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : The aim of this study is to evaluate the Temporal Anterior Chamber Depth (TACD) measured with anterior segment Swept-Source Optical Coherence Tomography (SS-OCT) and its association with the Van Herick Test evaluated clinically and with the temporal and nasal angles measured with the anterior segment SS-OCT.

Methods : Subjects with glaucoma presenting typical ONH findings, high intraocular pressure with or without visual field (VF) damage and normal subjects were included. Patients underwent SS-OCT (DRI-Triton, Topcon) of the posterior and anterior segments. A 3mm length vertical B-scan of the peripheral temporal anterior chamber was obtained with the edges of the scan adjacent to the limbus (figure 1). The TACD was the average of 5 manual measurements of the depth 500 microns apart from the cornea to the iris using the caliper of the software of the SS-OCT (ImageNet 6, Topcon). Gonioscopy and a photograph of the slit lamp based Van Herick test (VHT) that evaluates the anterior chamber depth (0 to 100) were performed. The temporal angle and nasal angle were obtained with single 3mm length horizontal B-scans, and their measurements were also performed manually using the software of the device. Statistical analysis was performed using Linear Mixed Models Test and Pearson Correlation Coefficient.

Results : 32 eyes from 19 subjects were included. The mean (SD) age was 58.63±10.34. Mean (SD) circumpapillary RNFL (retinal nerve fiber layer) of the sample was 99.47 ±17.36 µm. The mean (SD) measurements were: TACD: 405.82±161.93 µm; Temporal Angle: 26.08±10.80 degrees; Nasal Angle: 25.47±11.33 degrees; VHT: 63.44±32.46. TACD was significantly associated with temporal angle (p<0.001); nasal angle (p<0.001) and VHT (p=0.001). TACD was also significantly correlated (p<0.001) with temporal angle (r=.737); nasal angle (r=.779) and VHT (r=.589).

Conclusions : TACD was significantly associated with the clinical evaluation of the VHT and with the measurements of the temporal and nasal angles. This parameter can be potentially useful as a novel biomarker for screening and evaluation of angle closure glaucoma using anterior segment SS-OCT.

This abstract was presented at the 2023 ARVO Annual Meeting, held in New Orleans, LA, April 23-27, 2023.

 

Figures 1 and 2 depict horizontal B-scans of the temporal angle (A) with the corresponding vertical B-scan of the peripheral anterior chamber (B) used to measure TACD.

Figures 1 and 2 depict horizontal B-scans of the temporal angle (A) with the corresponding vertical B-scan of the peripheral anterior chamber (B) used to measure TACD.

 

×
×