ARVO Annual Meeting Abstract  |   June 2023
Comparison of Rates of RNFL Change Between Two Optical Coherence Tomography Devices
Author Affiliations & Notes
  • Iris Zhuang
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Vahid Mohammadzadeh
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Andrea Yonge
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Justin Park
    University of Michigan W K Kellogg Eye Center, Ann Arbor, Michigan, United States
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Massood Mohammadi
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Erica Su
    Biostatistics, University of California Los Angeles Jonathan and Karin Fielding School of Public Health, Los Angeles, California, United States
  • David Zhang
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Joseph Caprioli
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Robert E Weiss
    Biostatistics, University of California Los Angeles Jonathan and Karin Fielding School of Public Health, Los Angeles, California, United States
  • Kouros Nouri-Mahdavi
    Jules Stein Eye Institute, Los Angeles, California, United States
  • Footnotes
    Commercial Relationships   Iris Zhuang None; Vahid Mohammadzadeh None; Andrea Yonge None; Justin Park None; Massood Mohammadi None; Erica Su None; David Zhang None; Joseph Caprioli None; Robert Weiss None; Kouros Nouri-Mahdavi Heidelberg Engineering, Code F (Financial Support)
  • Footnotes
    Support  NIH R01 (EY029792), Departmental Grant from Research to Prevent Blindness, Heidelberg Engineering, Payden Glaucoma Research Fund, Simms/Mann Family Foundation
Investigative Ophthalmology & Visual Science June 2023, Vol.64, 2037. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Iris Zhuang, Vahid Mohammadzadeh, Andrea Yonge, Justin Park, Massood Mohammadi, Erica Su, David Zhang, Joseph Caprioli, Robert E Weiss, Kouros Nouri-Mahdavi; Comparison of Rates of RNFL Change Between Two Optical Coherence Tomography Devices. Invest. Ophthalmol. Vis. Sci. 2023;64(8):2037.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To compare rates of retinal nerve fiber layer (RNFL) thickness change between two commercially available optical coherence tomography (OCT) devices.

Methods : Ninety-five eyes (95 patients) with central visual field (VF) damage with ≥2 years of follow-up and ≥4 visits were included. RNFL OCT was acquired with Spectralis spectral-domain OCT (single circle) and Cirrus high-definition OCT (Optic Disc Cube 200×200) on the same visit. Rates of change of RNFL thickness globally and in 12 clock hour sectors were estimated with simple linear regression (SLR). Outcomes of interest were absolute rates of RNFL change and the proportion of significant negative (slope<0 and p<0.05) and positive (slope>0 and p<0.05) RNFL slopes. We also identified significant progressors with permutation analyses for each sector and globally. Significantly negative slopes fell in the tails below the 2.5% cutoff point. We compared the proportion of significant slopes between the devices with McNemar’s test.

Results : The mean (SD) baseline visual field mean deviation and mean (range) follow-up time were –8.2 (5.5) dB and 4.5 (2.2-6.7) years, respectively. The mean (SD) baseline global RNFL thickness was 61.4 (12.5) and 65.3 (10.0) μm for the Spectralis and Cirrus devices, respectively. The rates of RNFL change were significantly faster for Spectralis OCT compared to Cirrus OCT globally (–0.69; 95% CI: –0.90, –0.48 μm/year vs. –0.44; 95% CI: –0.71, –0.16 μm/year, p<0.001) and in most sectors (Figure 1). The proportion of significant negative slopes based on permutation analysis matched that of SLR, with a significantly higher proportion of progressing sectors in clock hours 3-6 and 8 for Spectralis OCT compared to Cirrus OCT, corresponding to the nasal, inferonasal, and inferotemporal regions (Table 1). The proportion of significant positive slopes was small and similar between the devices globally and for all sectors.

Conclusions : In this cohort of eyes with central or moderate to severe glaucoma, Spectralis OCT measurements tended to be faster and more likely to detect RNFL thinning over time compared to Cirrus OCT. OCT devices are not comparable with regard to detection of structural change in eyes with moderate to severe glaucoma damage.

This abstract was presented at the 2023 ARVO Annual Meeting, held in New Orleans, LA, April 23-27, 2023.

 

Figure 1. Box plot demonstrates rates of RNFL change globally and at each clock hour sector as measured with Cirrus and Spectralis OCT devices.

Figure 1. Box plot demonstrates rates of RNFL change globally and at each clock hour sector as measured with Cirrus and Spectralis OCT devices.

 

×
×