Investigative Ophthalmology & Visual Science Cover Image for Volume 65, Issue 7
June 2024
Volume 65, Issue 7
Open Access
ARVO Annual Meeting Abstract  |   June 2024
Ocular alignment evaluation using a novel software application running on a virtual reality headset
Author Affiliations & Notes
  • Nour Abou Shousha
    University of Miami Health System Bascom Palmer Eye Institute, Miami, Florida, United States
    Pine Crest School, Fort Lauderdale, Florida, United States
  • Alex Miller
    Heru, Florida, United States
  • Esdras A Arrieta
    University of Miami Health System Bascom Palmer Eye Institute, Miami, Florida, United States
  • Georgeana Mijares
    University of Miami Health System Bascom Palmer Eye Institute, Miami, Florida, United States
  • Maria Matosas
    University of Miami Health System Bascom Palmer Eye Institute, Miami, Florida, United States
  • Rashed Kashem
    Heru, Florida, United States
  • Gustavo Gameiro
    University of Miami Health System Bascom Palmer Eye Institute, Miami, Florida, United States
  • Mohamed Abou Shousha
    University of Miami Health System Bascom Palmer Eye Institute, Miami, Florida, United States
  • John McSoley
    University of Miami Health System Bascom Palmer Eye Institute, Miami, Florida, United States
  • Footnotes
    Commercial Relationships   Nour Abou Shousha None; Alex Miller Heru, Code E (Employment); Esdras Arrieta None; Georgeana Mijares None; Maria Matosas None; Rashed Kashem Heru, Code E (Employment); Gustavo Gameiro None; Mohamed Abou Shousha Heru, Code I (Personal Financial Interest), University of Miami, Code P (Patent); John McSoley None
  • Footnotes
    Support  Research to Prevent Blindness (RPB).
Investigative Ophthalmology & Visual Science June 2024, Vol.65, 5492. doi:
  • Views
  • Share
  • Tools
    • Alerts
      ×
      This feature is available to authenticated users only.
      Sign In or Create an Account ×
    • Get Citation

      Nour Abou Shousha, Alex Miller, Esdras A Arrieta, Georgeana Mijares, Maria Matosas, Rashed Kashem, Gustavo Gameiro, Mohamed Abou Shousha, John McSoley; Ocular alignment evaluation using a novel software application running on a virtual reality headset. Invest. Ophthalmol. Vis. Sci. 2024;65(7):5492.

      Download citation file:


      © ARVO (1962-2015); The Authors (2016-present)

      ×
  • Supplements
Abstract

Purpose : To evaluate the use of a novel software application downloadable on a virtual reality (VR) headset in assessing ocular alignment.

Methods : This prospective case-control study included 65 patients. Each patient underwent near and distant cover tests performed by a masked ophthalmologists (130 cover tests; 51 ortho, 36 phoria, and 43 tropia). Additionally, each patient received near and distant digital cover tests using the Heru cover test software application (Heru, Inc, Miami) that was downloaded on a VR headset equipped with an infrared pupil tracker (Pico Neo 3 Pro Eye, ByteDance, Beijing, China). In the digital cover test, patients were instructed to maintain fixation on visual targets presented on the screen of the VR headset in front of each eye in an alternating manner, while the pupil tracker recorded the resulting eye movements. The ocular deviations were measured in a subset of consecutive tropia patients (20 positive cover tests: 12 near cover tests in 12 tropic patients and 8 distance cover tests in 8 tropic patients) and compared to the clinically measured ocular alignments.

Results : The digital cover test differentiated between the alignment statuses of the ortho, phoria, and tropia patients in a highly significant manner compared to the clinical diagnosis (P<0.001). In the subset of cover tests where tropia was present and quantified, the mean deviation measured clinically was 17 prism diopters (PD, ±13 PD), while that measured with the digital cover test was 13 PD (±10 PD). The magnitude of the tropia measured using the digital cover test very strongly correlated with that measured clinically (r=0.813; P<0.001, Pearson Correlation).

Conclusions : The digital cover test in the VR headset can be used in the diagnosis of ocular misalignment. The ocular deviation measured with the digital cover test correlates very strongly with the clinically measured ocular deviation.

This abstract was presented at the 2024 ARVO Annual Meeting, held in Seattle, WA, May 5-9, 2024.

×
×

This PDF is available to Subscribers Only

Sign in or purchase a subscription to access this content. ×

You must be signed into an individual account to use this feature.

×